Asenware is a well-reputed company because of its products in the design and manufacturing of advanced alarm systems and fire alarm control panels. Asenware conventional fire alarm system is designed with items that are very reliable and user-friendly. Conventional fire alarm system provides necessary protection in building different ranges and complications.
But Universal Fire Protection in Islamabad, Karachi, and Lahore provides the products of the Asenware Conventional Fire alarm system. The products include Different types and models.
The Asenware Photoelectric Smoke detector is an important factor in a Conventional fire alarm System to reveal the presence of smoke in the environment. Asenware detector also detects the presence of smoke particles. When light enters the detection chamber, the smoke detector scatters the light onto the sensitive sensor due to the internal LED and activates the alarm.
Asenware conventional fire alarm system has a double sensor for fire detection that provides the advantage of photoelectric smoke detection and heat detection. The operational voltage is 9 to 28 VDC. Asenware conventional fire alarm system is installed in residential, commercial and industrial places.
This model of Asenware conventional fire alarm system also has dual sensing technologies, a photoelectric sensor for detecting smoke, and a heat sensor for detecting temperature. In addition, the specification of voltage is between 9V to 30V. During operation, the utilization would be around 30 to 50mA.
The main function of this model Asenware conventional fire alarm system is to detect fire and smoke by using detectors and activating an alarm. The voltage capacity is 24VDC. However, the Asenware device has a digital display with a flash and buzzer to show each Zone. The operating temperature is typically in the range of 0°to 50°. The utilization power relies on the number of detectors and devices but is generally around 100mA to 500mA.
Heat detectors fall into two categories ; rate of rise and fixed temperature detectors. When a fire is occurs anywhere the burning of material could generate a large amount of heat and in this way increase the temperature of the environment. If the temperature increases in an area by a specific rate it will trigger an alarm.
The Asenware conventional fire alarm system visualized the temperature. The operational voltage rate is 24VDC and the current consumption is 10mA to 30mA that is depending on the design and heat detector. Universal Fire Protection provides different models of heat detectors with specifications and excellent quality.
Asenware conventional fire alarm system which is very helpful for fire safety. But the general battery voltage is 12VDC or 24VDC and the power consumption range is between 10 to 20W. Heat detector is used in Fire alarm systems to detect and monitor fire environments.
The AW-CTD321 model is used as a fire alarm system for detecting the temperature. These heat detectors operate within a voltage 12VDC or 24DVC and the power supply is commonly 10mA to 30mA. It is installed in areas where the smoke detectors are not suitable like kitchen garages where high dust and smoke.
Asenware designed this model with operating efficiency. It has a specification with a different range. This heat detector has a typical voltage range of 24V DC. Furthermore, the system generally uses 3 – 10W in standby mode during alarm conditions and use in commercial, residential, industrial, and public buildings.
Standalone smoke detector is a key feature Of Asenware conventional fire alarm systems. The standalone detector works as a safety device designed to detect temperature variations associated with a fire and operates independently of a fire alarm control panel. It may not be integrated into a larger fire detection system. People generally install this device in areas where smoke detectors are not suitable, such as kitchens, garages, or industrial settings. Smoke detectors are cost-effective and generally installed in smaller places.
Types of Standalone detectors
Asenware fire alarm system that is manufactured to monitor temperature changes in an environment. The typical voltage range is 9V to 30V DC and the power consumption is 5 – 20mA.In addition, this is used in various environments where an excess temperature indicates a fire condition. On the other hand, Some common applications such as commercial and residential buildings and elevator shafts.
Asenware smoke detector that is used in safety applications. This model has a Voltage range of 9V – 30V DC. This detector draws minimal current, often in the range of ≤ 20 m which is standard for low-power standalone detectors. Moreover, you can install it in data centers or server rooms.
This device is designed to detect the heat changes in the environment which may indicate a fire or other disaster system. The voltage of this model is 9V DC or 12V DC. Some models are designed 24V DC for larger systems, commonly installed in industrial or commercial places. In addition, this model has a low power, generally in the range of a few milliamps.
The heat-sensitive detector manufactured for fire detection with a wide voltage range is 9V DC -30V DC power supply and low power requirements which is less than 10mA. However, the detectors primarily used for detecting temperature increases caused by fires. People use this detector of Asenware conventional fire alarm system in warehouses, storage areas, Safety compliance, homes, or small buildings.
The LPG gas detector is a safety equipment that is designed to detect the presence of liquified petroleum gas in the air.Asenware detectors are commonly used in commercial residential and industrial settings to prevent hazards such as gas leaks which could lead to explosions or fire. Because the operating voltage for AC is 90V – 270V and DC is 9 – 28V. Universal Fire Protection provides the LPG gas detector and also its models at affordable rates.
The Asenware conventional fire alarm system is used to detect the liquified petroleum gas in the environment. The typical voltage range is 5VDC. Whereas, the power consumption is around <150mA at 5V DC. people use this model in kitchens, homes, factories, and any space where LPG is used or stored.
This model detects the presence of petroleum liquid gas in the environment and is typically installed in areas where LPG is stored. Such as in Kitchens, homes and industrial places. on the other hand, The fire alarm system provides a guide for early leaks of gas. The voltage range is 12VDC or 24VDC depending on the model.
The manual call point function is to sign in an alarm in a fire emergency. The voltage range of this model is 12V DC to 24V DC. Therefore, the average current is usually less than 5mA in standby mode. This Asenware conventional fire alarm system has a top-notch solution.
The manual call point AW-CMC2166-6 has an essential factor that allows it to activate the fire alarm in case of a fire emergency. This model’s of Asenware conventional fire alarm system operating voltage range is 24VDC. Furthermore, the power current is in the range of 10 to 20mA in standby mode but increases in value during the triggering alarm.
The Asenware fire bell activates alarms during emergency conditions. The bell runs at a voltage rate of 24V DC. These Fire Bells run with a working current of 50mA andl are commonly used in public and industrial buildings.
This alarm system analyse fire and serves as a protection device fix in builings. Hornstrobe is a key form of fire alarm system that operates on a zone-based detection methodology. The Horn Strobe has also different models with specific voltage and working currents.
The Flashlight is a dual-type device in the Asenware conventional fire alarm system. It acts as both a visual and auditory alerting device installed in fire alarm and emergency warning system In addition, It has a flashing light and a loud audible alarm. As a result, the strobe flashes bright light to provide an alert in noisy environments.
The entrance indicator is an important feature of Asenware conventional fire alarm system. It alerts the people about the presence of fire at the entrance and exit of buildings. The indicator provides an early alert to those areas where fire risks and ensures their safety.