<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hybrid Fire Suppression Systems Archives - Universal Fire Protection Co. Pvt Ltd</title>
	<atom:link href="https://universalfireprotection.com.pk/tag/hybrid-fire-suppression-systems/feed/" rel="self" type="application/rss+xml" />
	<link>https://universalfireprotection.com.pk/tag/hybrid-fire-suppression-systems/</link>
	<description>Universal Fire Protection Co. Pvt Ltd</description>
	<lastBuildDate>Fri, 28 Mar 2025 07:38:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://universalfireprotection.com.pk/wp-content/uploads/2021/02/cropped-logo-32x32.png</url>
	<title>Hybrid Fire Suppression Systems Archives - Universal Fire Protection Co. Pvt Ltd</title>
	<link>https://universalfireprotection.com.pk/tag/hybrid-fire-suppression-systems/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Hybrid Fire Suppression Systems</title>
		<link>https://universalfireprotection.com.pk/hybrid-fire-suppression-systems-watermist-budget/</link>
		
		<dc:creator><![CDATA[Admin User]]></dc:creator>
		<pubDate>Thu, 30 Nov 2017 07:10:31 +0000</pubDate>
				<category><![CDATA[AKRONEX Italy]]></category>
		<category><![CDATA[Hybrid Fire Suppression System]]></category>
		<category><![CDATA[Hybrid Fire Suppression Systems]]></category>
		<category><![CDATA[Hybrid Fire Suppression Systems in Pakistan]]></category>
		<guid isPermaLink="false">http://www.universalfireprotection.com.pk/?p=1620</guid>

					<description><![CDATA[&#160; Water is the oldest but most effective fire suppression agent. Water still is protecting its effecience and importance on suppression due to its cooling and evaporation effect. However, Conventional suppression systems use big water drops on small suppression areas and water consumption is very high. The goods inside the affected area can be damaged because of the usage plenty of water. Hybrid Fire Suppression [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p style="text-align: justify;">Water is the oldest but most effective fire suppression agent. Water still is protecting its effecience and importance on suppression due to its cooling and evaporation effect. However, Conventional suppression systems use big water drops on small suppression areas and water consumption is very high. The goods inside the affected area can be damaged because of the usage plenty of water.</p>
<p style="text-align: justify;"><strong>Hybrid Fire Suppression System</strong></p>
<p style="text-align: justify;"><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-1624" src="http://www.universalfireprotection.com.pk/wp-content/uploads/2017/11/Hybrid-Fire-Suppression-Systems-Watermist.jpg" alt="Hybrid Fire Suppression Systems (Watermist)" width="615" height="350" srcset="https://universalfireprotection.com.pk/wp-content/uploads/2017/11/Hybrid-Fire-Suppression-Systems-Watermist.jpg 615w, https://universalfireprotection.com.pk/wp-content/uploads/2017/11/Hybrid-Fire-Suppression-Systems-Watermist-300x171.jpg 300w" sizes="(max-width: 615px) 100vw, 615px" /></p>
<p style="text-align: justify;">AKRONEX hybrid system uses water as a natural agent and represent AKRONEX’s scope expertise of extinguishing. AKRONEX also supports risk assessment, system design, installation and operation and support. But the Hybrid Fire Protection System extinguishes open spaces and growing fires effectively and quickly at low hydraulic pressure. Unique two-phase flow technology separates the water and gas mixture into fine (atomized size) water droplets.</p>
<p style="text-align: justify;">Furthermore, a Hybrid system can be applied for the protection of rooms and objects. The Hybrid system has become an effective extinguishing system by optimizing the physical properties of the water through the system. But In Hybrid system applications, pressurized water and gas mixture with 85-100 bar is pulverized with special nozzles and discharged at high speed.</p>
<p style="text-align: justify;"><b>SYSTEM WORKING PRINCIPLE</b></p>
<p style="text-align: justify;">Hybrid system use a similar system with conventional fire extinguishing systems. But this time the water droplets (less than 10 microns) are 100 times smaller than 1 water drop. Hybrid system uses less water than the conventional system emits 50% more emissions and completely extinguishes. Unlike other systems, the <a href="https://universalfireprotection.com.pk/akronex-inert-fire-suppression-systems/">AKRONEX inert suppression system</a> utilizes both water and nitrogen at the best level. However, Water and nitrogen complement each other at perfect levels and extinguish the fire.</p>
<p style="text-align: justify;">For small fires, nitrogen is the main fire-fighting agent. However, The Hybrid system reduces the oxygen in the area to the breathable level. The homogeneous mixture of water droplets and nitrogen gas is propelled with enough energy to overcome the drag effect.But that has limited the effectiveness of traditional water mist systems.<br />
<img decoding="async" class="aligncenter wp-image-1625" src="http://www.universalfireprotection.com.pk/wp-content/uploads/2017/11/Hybrid-Fire-Suppression-Systems.jpg" alt="Hybrid Fire Suppression Systems" width="520" height="832" srcset="https://universalfireprotection.com.pk/wp-content/uploads/2017/11/Hybrid-Fire-Suppression-Systems.jpg 640w, https://universalfireprotection.com.pk/wp-content/uploads/2017/11/Hybrid-Fire-Suppression-Systems-187x300.jpg 187w" sizes="(max-width: 520px) 100vw, 520px" /></p>
<ul style="text-align: justify;">
<li>Thanks to evaporation, it cools the temperature of the gases caused by the flame. But the surrounding fire and removes oxygen from the area,</li>
<li>Attenuating radiant heat by the small droplets themselves,</li>
<li>85-200 bar pressurized water in hybrid system applications is pulverized with special nozzles and charged at high speed. The resulting water gas mixture occupies 1800 times more volume than the liquid phase of the water. Oxygen level in the area reduced to 12-15%,</li>
</ul>
<p style="text-align: justify;">The effectiveness of a hybrid system in fire suppression depends on its spray characteristics, which include the droplet size distribution, flux density and spray dynamics, with respect to the fire scenario, such as the shielding of the fuel, fire size and ventilation conditions.</p>
<p style="text-align: justify;"><b>ADVANTAGES<br />
</b>[su_list icon=&#8221;icon: check-circle&#8221; icon_color=&#8221;#d7693f&#8221;]</p>
<ul>
<li>Immediate activation upon detection of a fire- no need to wait for evacuation and countdown before discharge</li>
<li>High efficiency in the suppression of a wide variety of fires,</li>
<li>Nearly zero wetting</li>
<li>Minimum water damage,</li>
<li>Environmentally sound characteristics</li>
<li>No toxic problems,</li>
<li>Effecience on flammable liquids,</li>
<li>Open space effectiveness,</li>
<li>Easy and Quick system recharge,</li>
<li>Self-contained</li>
<li>No need for assurance of tight room integrity<br />
[/su_list]</p>
<p style="text-align: justify;"><b>WHY HYBRID SYSTEM?</b></p>
<p style="text-align: justify;">AKRONEX hybrid system extinguish fire actively without harm people. Today, AKRONEX protects people, property and business continuity in a wide range of applications both on land and at sea.</p>
<ul style="text-align: justify;">
<li>Better penetration into the seat of the fire,</li>
<li>Superior coverage of the protected volume,</li>
<li>An improved cooling effect from better mixing of gases and high evaporation rate,</li>
<li>Lower overall system weight,</li>
<li>Less water consumption,</li>
</ul>
<p style="text-align: justify;"><b>USAGE AREAS</b></p>
</li>
</ul>
<ul>
<li>Chemical paint stores,</li>
<li>Explosive and flammable cosmetic warehouses,</li>
<li>In turbine generators,</li>
<li>Emergency generators,</li>
<li>Fuel pumps, Fuel tanks,</li>
<li>In oil tanks,</li>
<li>In engine test rooms</li>
<li>Hydraulic pump rooms</li>
<li>In tunnel fires</li>
<li>Electrostatic coating, immersion,</li>
<li>Museums</li>
<li>Libraries</li>
<li>Motor control center room</li>
</ul>


<div class="kk-star-ratings kksr-auto kksr-align-center kksr-valign-bottom"
    data-payload='{&quot;align&quot;:&quot;center&quot;,&quot;id&quot;:&quot;1620&quot;,&quot;slug&quot;:&quot;default&quot;,&quot;valign&quot;:&quot;bottom&quot;,&quot;ignore&quot;:&quot;&quot;,&quot;reference&quot;:&quot;auto&quot;,&quot;class&quot;:&quot;&quot;,&quot;count&quot;:&quot;102&quot;,&quot;legendonly&quot;:&quot;&quot;,&quot;readonly&quot;:&quot;&quot;,&quot;score&quot;:&quot;5&quot;,&quot;starsonly&quot;:&quot;&quot;,&quot;best&quot;:&quot;5&quot;,&quot;gap&quot;:&quot;5&quot;,&quot;greet&quot;:&quot;Rate this post&quot;,&quot;legend&quot;:&quot;5\/5 - (102 votes)&quot;,&quot;size&quot;:&quot;24&quot;,&quot;title&quot;:&quot;Hybrid Fire Suppression Systems&quot;,&quot;width&quot;:&quot;142.5&quot;,&quot;_legend&quot;:&quot;{score}\/{best} - ({count} {votes})&quot;,&quot;font_factor&quot;:&quot;1.25&quot;}'>
            
<div class="kksr-stars">
    
<div class="kksr-stars-inactive">
            <div class="kksr-star" data-star="1" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" data-star="2" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" data-star="3" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" data-star="4" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" data-star="5" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
    </div>
    
<div class="kksr-stars-active" style="width: 142.5px;">
            <div class="kksr-star" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
            <div class="kksr-star" style="padding-right: 5px">
            

<div class="kksr-icon" style="width: 24px; height: 24px;"></div>
        </div>
    </div>
</div>
                

<div class="kksr-legend" style="font-size: 19.2px;">
            5/5 - (102 votes)    </div>
    </div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
